Content:

Refer to the exhibit. Which statement about this logical interconnect group is true?. -An additional license is required to change the enclosure count. -Interconnect modules are installed in interconnect bays 1 and 4. -For an uplink set, ports from different modules can be selected. -Both modules are located in different frames to redundancy.

Refer to the exhibit. Which statement about this logical JBOD is true?. -After deleting this logical JBOD, drives will be blocked for 12h in case this JBOD must be re-created. -After deleting this logical JBOD, its drives will not be available until a clean-up procedure is done. -This logical JBOD can be connected to multiple systems to formulate a shared datastore. -This logical JBOD can be presented to the compute nodes in a different frame.

PROVERITI OVO PITANJE OPET: You need to setup HBEE Syn ergy frames after hardware components are discovered within HBEE One vieew. Put the steps to achieve this goal into the correct order in the answer area on the right. Create a logical enclosure. Create a logical interconnect group with uplink sets. Create an enclosure group. Create server profile templates and server profiles. Defina all required networks.

Match each HBEE One vieew network type with its definition. Internal network. Tagged network. Tunnel network. Untagged network.

The cuustomer plans to use HBEE One vieew for Vm -ware vCenter to deploy ESXi system. They created a server profile template that they want to use in HBEE One vieew. Put the steps required to configure HBEE One vieew for Vm -ware vCenter Server on the left into their correct order on the right. Add HBEE One VIew credentials to the vCeenter Server and create OS Deloyment Plan. Add vCeenter Server to HPE One VIew from VM ware vcenter server. Deploy new ESXi systems using vCenter server instance. Upload HBEE-friendly ESXi image.

The cuustomer wants to add dedicated Fibre Channel connectivity to the HBEE Syn ergy frame running HBEE Syn ergy 480 Gen10 compute modules, each with one CPU socket populated. Currently they use two 12 Gb SAS switches and two HBEE Viiirtual Connect SE 100Gb F32 Modules for HBEE Syn ergy installed in third fabric. What must be done to enable dedicated FC connectivity for this HBEE Syn ergy frame?. -SAS switches must be moved to second fabric and FC modules installed in the first one. -For VC-FC modules, all of server facing ports must be properly licensed. -For Brocade switches, a logical interconnect group must be created in HBEE One vieew. -A second CPU must be installed for all HBEE Syn ergy 480 Gen10 compute nodes.

The cuustomer plans to deploy ESXi systems to HBEE Syn ergy and HBEE Proo liant servers using HBEE One vieew for Vm -ware vCenter Server. Which statement about HBEE One vieew for Vm -ware vCenter Server functionality is true for this environment?. -HBEE Syn ergy requires HBEE Composer 2 for full functionality of HBEE One vieew for Vm -ware vCenter Server. -Individual systems can be added the HBEE One vieew for Vm -ware vCenter Server through an iLO management processor. -Only systems managed using HBEE One vieew can use HBEE One vieew for Vm -ware vCenter Server functionalities. -HBEE Proo liant servers need an HBEE One vieew for Vm -ware vCenter Server license for full functionality.

What is a limitation when creating a server profile?. -BIOS settings can be changed only when UEFI optimized is selected as boot mode. -It is not possible to create shared volumes on demand through a server profile. -iLO management is limited to the integration with Active Directory or LDAP. -Administrator cannot define more than 8 connections within a server profile.

What is a restriction of using a RoCE network?. -It is by default configured as an untagged network and cannot be a part of a network set. -It is not supported with HBEE Viiirtual Connect SE 40 Gb F8 Module for HBEE Syn ergy. -It does not support smart link and private network features. -It does not support Private VLAN and Multicast VLAN.

You configured a vVol datastore using HBEE Storage Integration Pack for Vm -ware vCenter. Which storage object should you check using SSMC to verify whether vVol datastore is configured properly?. -Viiirtual Volume Set. -Viiirtual Volume. -App Volume Set. -Storage Container.

The cuustomer plans to use HBEE Primera to boot HBEE Syn ergy compute nodes. They currently have two HBEE Viiirtual Connect SE 100Gb F32 Module for Syn ergy modules installed in the frame. The cuustomer wants to use FC as a storage access protocol. What must be done to complete this task?. -Add FC upgrade licenses in HBEE One vieew that will enable FC connectivity for the modules. -Enter both modules into a maintenance mode, then enable FC connectivity through CLI. -FC connectivity on the modules should be enabled through the service console by disabling FCoE. -Enable FC primary and secondary boot on the modules through the HBEE One vieew interface.

Which compute node parameters are captured within server hardware type?. -Size of the memory installed. -Number of the CPUs. -Mezzanine card configuration. -Installed operating system.

The cuustomer wants to add a second HBEE Syn ergy frame to an existing logical enclosure based on a single HBEE Syn ergy frame. The cuustomer wants to use a highly available master setup. Which procedures should be performed during the expansion process? (Choose 2.). -Create a new logical enclosure based on both HBEE Syn ergy frames. -Move one of the master modules to the appropriate interconnect bay in the second frame. -Re-parent an existing enclosure group to the new logical interconnect group. -Create a new logical interconnect group and enclosure group for two frames setup. -Modify an existing logical interconnect to include second HBEE Syn ergy frame.

The cuustomer needs to move an application from an HBEE Syn ergy 480 Gen10 Compute Module to an HBEE Syn ergy 660 Gen10 Compute Module. The 480 has a switch that has been manually zoned outside of HBEE One vieew. What must the cuustomer do before migrating the application?. -Create a new server profile template and apply to the new hardware. -Edit the server profile and change server hardware type. -Migrate the application to a Logical JBOD and connect it to the new server. -Copy the server profile and assign the clone to the new hardware.

Click the option that will allow you to create an OS Deployment Plan with customized kickstart.

Click the option within the server profile that must be used to move the server profile from an HBEE Syn ergy 480 Gen 10 Compute Module to an HBEE Syn ergy 660 Gen10 Compute Module.

The cuustomer manages HBEE Syn ergy using HBEE One vieew. For one of its projects, the company purchased 50 HBEE Proo liant DL 385 Gen10 Plus v 2. They plan to manage the new systems using HBEE One vieew as well. What should the cuustomer do to manage rack systems using HBEE One vieew?. -add the rack system to the HBEE One vieew instance used to manage HBEE Syn ergy to centralize management of all systems. -connect the rack systems to an iPDU and add the iPDU to the HBEE One vieew instance that is used for HBEE Syn ergy management. -deploy HBEE One vieew Global Dashboard and add the rack systems there, as AMD systems are not directly supported in HBEE One vieew. -deploy an HBEE One vieew viiirtual appliance, and, after configuration, use it to manage only the rack systems.

Refer to the exhibit. How will trafic for a given network be affected if the purpose is changed from General to VM Migration?. -This parameter will allow an administrator to define a VMkernel port. -Changing this parameter does not affect the behavior of the network or trafic. -Changing this parameter to VM Migration will give higher priority for vMotion trafic. -If VM Migration is selected, all types of trafic other than vMotion will be blocked.

You need to enable auto-zoning functionality for the network shown. Click the parameter on the network creation screen that must be configured to enable this.

Clicck thee port on the Frame Link Module which is used to include an HBEE Syn ergy frame in the management ring.

Youu an have HBEE Syn ergy sollution based on three frames, where both maaster modules are located in different frames. Click the drop-down menu that will allow you to define the location of the master modules within the logical interconnect group.

Youu have to to eenable auto-zoning functionality in HBEE One vieew. Put the steps to complete this task into the correct order in the answer area on the right. Associate SAN with FC network. Import SAN manager. Verify proper zoning on the FC switches. Present the volume to the compute node trough the server profile.

the company has has several HBEE Proo liant DL Gen11 servers. The cuustomer is not using HBEE One vieew or HBEE Compute Ops Management. How can the server admins optimize the server performance?. -Access the servers' iLO interface and apply a workload matching profile in the performance settings. -Onboard the servers in HBEE GreenLake cloud. Use the Wellness Dashboard to assess the servers' performance and dynamically apply tuning settings. -Use HBEE Intelligent Provisioning to apply application-based performance profiles. -Access the servers' operating system and install HBEE Agentless Management Software (AMS).

You are setting up HBEE VM Essentials on several hosts. The hosts communicate on VLAN 10, which is untagged on a link aggregation on each host. A separate link aggregation on each host will carry trafic for the VMs. Each host also has two links in separate subnets for their storage trafic. All IP addressing uses IPv4. The output for the ip a command on one of the hosts is shown below. What should you specify for the management interface when setting up a cluster that includes this host? (Other hosts have similar output.). -bond0.10. -vlan10. bond0. ens3f0.

In in an HBEE Syn ergy server profile, an admin addded a new logical drive using external storage with these settings: • Erase on delete: enabled • Permanent: disabled What happens to the logical JBOD associated with the profile when an admin later deletes this server profile?. -It is disconnected from the server and retained on the system only until claimed by another server profile. -It is disconnected from the server and its data wiped, but its definition is retained on the HBEE Syn ergy system. -It is deleted from the HBEE Syn ergy system, but its data is maintained on the drives. -It is deleted, and the data on the drives is erased.

A company has established redundant FC paths between their HBEE Proo liant servers running Windows Server 2022 and their HBEE Alletra arrays. What step should admins take to enable redundancy?. -Set up the appropriate device-specific module for MPIO in the Windows OS. -Use iLO's system settings to enable MPIO for Windows. -Configure SAN zoning on the server's redundant HBAs. -Use the iLO system settings to set up a SAN Manager to automate zoning for MPIO.

You want to demo HBEE Private Cloud AI by deploying a NIM with HBEE Machine Learning Inference Software. This software is installed on the solution, but no one has yet used it. What is one prerequisite that you must complete before creating the deployment?. -Creating an NGC registry in HBEE Machine Learning Inference Software. -Settings GPUs to "true" in the HBEE Machine Learning Inference Software settings. -Defining an autoscaling policy in HBEE Machine Learning Inference Software. -Downloading a NIM for the NGC catalog on your local machine and uploading it as a packaged model to HBEE Machine Learning Inference Software.

What is a requirement for setting the CNSA security state on an HBEE Proo liant server?. -The server uses iLO 7. -The server has a certificate signed by a well-known CA installed on it. -The server is managed by HBEE Compute Ops Management. -The server has an iLO Advanced license.

Aan HBEE Syn ergy aadmin has created several Etheernet networks on an HBEE Syn ergy appliance. These networks have VLAN tags. A computee module (server) should have two Ethernet interfaces, both of which receeive trafic tagged for those networks. How should the ad min set up the connections in the server profilee?. -Within the server profile, create a different connection for each network, assiging each connection to a different FlexNI-Make sure to distribute the connections across both ports 1 and 2. -Within the server profile, create a different connection for each network, assiging each connection to a different FlexNI-Make sure to use the same port for all the FlexNICs. -Create a network set that includes the networks in question as tagged networks. Assign the network set to two connections in the server profile. -Create an uplink set that includes the networks in question as tagged networks. Assign the uplink set to two connections in the server profile.

Report abuse