545xaps
|
|
Title of test:
![]() 545xaps Description: this here |



| New Comment |
|---|
NO RECORDS |
|
The a cuustomer reports that they cannot deploy HBEE Syn ergy compute nodes using HBEE One vieew for Vm -ware vCenter Server (HBEE OV4VC). What should you check during troubleshooting process?. -If all compute nodes are added to the vCenter Server. -If HBEE One vieew credentials are added in vCenter Server. -If vCenter Server is licensed in the HBEE One vieew interface. -If the HBEE One vieew instance is integrated with HBEE OV4VC. You are troubleshooting an HBEE One vieew server profile that presents a critical state. The server profile was configured with a Link Aggregation Group. What should you check to fix the issue?. -If both FlexNICs are connected to different networks. -If both FlexNICs are configured with the same speed. -If the logical enclosure is built on at least three HBEE Syn ergy frames. -If the logical enclosure is configured with redundant master modules. The aa cuustomer has an HBEE Syn ergy frame equipped with a D3940 Storage Module. Each of the compute nodes has an appropriate storage controller installed and two 12Gb SAS switches installed in the first fabric. The cuustomer reports that compute nodes cannot access the storage module. What should you verify first when troubleshooting this problem?. -If the D3940 module is imported in managed state that allows volume provisioning. -If the D3940 module is imported in managed state that allows volume provisioning. -If there is at least one iSCSI network configured that will provide access to the module. -If there is a logical interconnect created based on the 12Gb SAS switches. The cuustomer added a new Ethernet network in HBEE One vieew that is used to manage their HBEE Syn ergy platform. When the cuustomer tries to connect one of the compute nodes to this network through the server profile, this network is not available. What must be done to fix this issue?. -Check within the server profile which server hardware is used, and perform the Refresh operation on this compute node to get the latest adapter information. -The newly created network must be added to the uplink set within the LIG, and Logical Interconnect configuration must be updated from the LIG. -Check the Logical Enclosure settings and verify if the maximum number of networks allowed for this LE is reached. -To make this network available to use in the server profile, the cuustomer must enable the Smart Link feature within network definition. Which statement about an HBEE One vieew support dump is true?. -Support dump is a binary file that can be opened only in a dedicated application. -All data in the support dump file is encrypted and accessible by authorized engineer. -Support dump can be created if HBEE Viiirtual Connect modules are installed in the frame. -Appliance support dump by default contains a logical enclosure support dump. aa cuustomer is trying to grow a Vm -ware cluster using HBEE One vieew for Vm -ware vCenter Server. They get an error and cannot proceed. Which tool should you use to troubleshoot the problem?. -vCenter Server to use the HBEE One vieew for Vm -ware vCenter plugin to import the cluster for HBEE One vieew management. -HBEE One vieew interface to import an existing cluster using the hypervisor cluster profile functionality. -iLO interface of a given HBEE Syn ergy compute node to verify whether this node is registered within HBEE One vieew. -HBEE One vieew for Vm -ware vCenter Server to verify if the server profile template is properly imported and registered. Which statement about port flap protection is true?. -It allows allows an administrator to suppress excessive inbound multicast, broadcast, and DLF packets. -It allows the creation of LACP groups on the upstream switch that span multiple HBEE Syn ergy Viiirtual Connect modules. -It allows configuration of hardware Layer 2 switching behavior of multicast trafic to optimize network resource usage. -It can disable link aggregation groups or stacking ports that have gone down and come up in quick succession. You discovered that somebody deleted the SSO certificate that affects accessing iLO from HBEE One vieew from an iLO processor in an HBEE Syn ergy compute node. How will you recover from this problem?. -Login to the HBEE Composer CLI and use the efuse procedure for the affected server. -Navigate to HBEE One vieew, locate the affected server hardware and use Refresh option. -Navigate to HBEE One vieew, locate the affected server hardware and use the Reset iLO option. -Remove the affected server from HBEE One vieew and add it again to reconfigure an iLO processor. Click the option that will allow you to change the ESXi image used in an OS Deployment Plan. After deploying HBEE Super dome Flex 280, you need to check Core Analysis Engine (CAE) Log. Click the appropriate section in the HBEE Super dome Flex 280 management interface that will allow you to complete this task. An administrator tries to open iLO interface from HBEE One vieew. Instead of being automatically logged in, a login prompt displays. Where should you start the troubleshooting process?. -At HBEE One vieew interface to verify whether the iLO processor is disabled. -At the iLO interface to verify whether the iLO Advanced license is properly applied. -At the iLO interface to verify whether the SSO certificate is removed from an iLO. -At HBEE One vieew interface to verify whether the server is in the maintenance mode. Which statement about manual orchestration during the firmware update is true?. -It is supported only for logical enclosures with at least three frames. -It provides an ability to select and update one side of the interconnect topology at time. -It provides the ability to install an older firmware version than currently installed in the interconnect. -It allows all the interconnect modules to be activated manually at the same time. Which HBEE Viiirtual Connect feature allows an administrator to suppress excessive inbound multicast, broadcast, and destination lookup failure (DLF) packets?. -Storm control. -LLDP tagging. -Loop protection. -Pause flood protection. Which statement about an HBEE One vieew support dump is true?. -Preview support dump is available only when creating an appliance support dump. -Appliance support dump by default contains a logical enclosure support dump. -Support dump is a binary file that can be opened only in a dedicated application. -Support dump can be created if HBEE Viiirtual Connect modules are installed in the frame. The cuustomer experienced some problems caused by outdated HBEE Super dome Flex firmware. Which update method should they use to avoid these issues in the future?. -RMC CLI to update I/O and HBEE Persistent Memory firmware. -HBEE One vieew if HBEE Persistent Memory firmware must be updated. -HBEE One vieew method for I/O firmware update procedure. -HBEE SUM if HBEE Persistent Memory firmware must be updated. Which tool can be used to evaluate the health of an HBEE One vieew appliance before proceeding with an appliance update?. -HBEE One vieew Global Dashboard. -HBEE Composer Maintenance Console. -HBEE One vieew Update Readiness Checker. -HBEE One vieew Firmware Compliance Report. Which statement about login redistribution is true?. -Login redistribution is used for login balancing when they are not distributed evenly over the FC links. -Login redistribution is supported only on the HBEE Syn ergy Viiirtual Connect SE 32Gb FC Modules. -Login redistribution is available only if HBEE Primera or HBEE Alletra is connected directly to the HBEE Syn ergy frame. -Login redistribution is a licensed feature and the number of licenses required depends on the number of active ports. The cuustomer reports that an external FC boot volume for Windows server is visible four times in the Disk Management: 1 online and 3 ofline. What should you do to resolve this issue?. -Remove the ofline disks using array management tools. -Remove the ofline disks using Windows Disk Management. -Install and configure MPIO on the Windows system. -Disable deduplication for this volume at the array level. Which statement about HBEE One vieew milestone releases is true?. -A milestone release is available for selected partners that gives access to HBEE One vieew features which are not oficially announced. -A milestone release is a release which must be installed on HBEE Composer to support current version of the Service Pack for Syn ergy. -A milestone release is a release that is published when HBEE releases new hardware components to immediately support new systems. -A milestone release is a release with an enhanced update architecture that is a prerequisite prior to updating to a subsequent release. In the past, a cuustomer experienced a networking issue where network ports went down and came back up in quick succession. Which HBEE Viiirtual Connect SE 100 Gb F32 Module for HBEE Syn ergy can be configured to disable such ports?. -Port flap protection. -sFlow. -Pause flood protection. -Storm control. You modified a logical interconnect group that is used to configure logical interconnects in five different logical enclosures. What will be the impact of that change?. -All logical interconnects configured using this logical interconnect group will report inconsistency. -All physical interconnects from the affected logical interconnects must be rebooted to activate the new configuration. -All logical interconnects configured using this logical interconnect group will be automatically updated. -All physical interconnects from affected logical interconnects will be placed in a maintenance mode. The cuustomer changed the storage pool state from managed to discovered. What is the impact of that change?. -Volume provisioning will be disabled for that storage pool. -This storage pool can be deleted using HBEE One vieew interface. -All volumes from that poll will be removed from HBEE One vieew. -Storage pool parameters cannot be modified using HBEE One vieew. One of the administrators added some connections within a server profile that was created using a template. This server profile did not report inconsistency. What is the most likely reason for this behavior?. -The server is in a maintenance mode and does not report any issues. -Connections defined in the server profile are not monitored for compliance. -The administrator removed FC connections that are not monitored by default. -Consistency check for connections is set to Minimum or Not checked. You configured a vVol datastore using HBEE Storage Integration Pack for Vm -ware vCenter. Click the option in the SSMC main menu that you can use to verify whether a vVol storage object is properly created on HBEE Primera or 3PAR. The cuustomer wants to update the firmware for 36 HBEE Syn ergy 480 Gen 10 compute modules with a server profile assigned from a server profile template. Put the steps required to achieve this goal on the left into their correct order on the right. Select Firmware baseline within server profile template. Select installation method (online or offline). Update all server profiles from the template. Upload SPP to HPE One View repository. Click the option that will allow you to update the HBEE Syn ergy logical enclosure firmware. The cuustomer used to manage their HBEE 3PAR arrays using HBEE One vieew. Now they have replaced these arrays with HBEE Primera. How does managing the new arrays compare to managing their old arrays?. -Management procedures and features are the same for both types of the array. -HBEE One vieew offers additional functionalities for HBEE Primera like CPG management. -HBEE One vieew offers limited support for HBEE Primera because of the firmware differences. -To manage HBEE Primera using HBEE One vieew, a dedicated license is required. Which statement about HBEE Super dome Flex firmware updates is true?. -HBEE SUM is the only tool that can be used to update HBEE Persistent Memory firmware. -RMC CLI is the only tool that can be used to update HBEE Persistent Memory firmware. -RMC CLI can simultaneously update complex firmware for multiple HBEE Super dome systems. -HBEE One vieew is the only tool that can be used to perform I/O updates. Which statement about the HBEE One vieew Update Readiness Checker is true?. -It can be used to examine the firmware version installed on compute nodes and compliance with HBEE One vieew version. -It can be used to verify compatibility of a given Syn ergy Service Pack with a specific version of HBEE One vieew. -It can be used to determine whether the latest milestone HBEE One vieew edition is currently installed. -It can be used to evaluate the health of an HBEE One vieew appliance before proceeding with an appliance update. Ann organizaation manages its HBEE Proo liant Gen11 servers, using iLO 6, in HBEE Compute Ops Management. What is one security risk that HBEE Compute Ops Management can detect?. -The server's iLO allows SNMPv1 requests. -The server's trafic patterns vary from normal. -The server is exposed to attack due to the lack of antivirus software. -The server has unencrypted data on its local drives. Admins want to use HBEE Compute Ops Management to apply a custom BIOS/Workload profile to several servers. What is a required part of the setup?. -They must ensure that the servers' BIOS settings are first set to factory defaults. -They must use the HBEE Compute Ops Management API to create the custom profile. -They must use iLO to configure the servers to boot in optimized UEFI mode. -They must ensure that the servers' OS does not attempt to control any of the settings that the custom profile controls. What role does Prometheus play in HBEE AI Essentials?. -It automates detecting drift in deployed models. -It cleans up idle applications to make room for new applications. -It gathers metrics and provides built-in alerting. -It authenticates and secures communications between workloads. What is one requirement for onboarding HBEE servers in HBEE Compute Ops Management? Assume that the activation key method will be used. -Servers have a supported operating system installed on them. -Servers with iLO dedicated network ports use that port, not an iLO shared network port. -Servers serial numbers and product IDs have been added to the HBEE GreenLake inventory. -Servers are discovered with HBEE One vieew. A cuustomer has HBEE Proo liant servers managed with HBEE Compute Ops Management and storage managed by HBEE Data Ops Manager. The cuustomer has Tech Care support for the HBEE solutions. The cuustomer also uses OpsRamp and has discovered all the HBEE infrastructure there. When troubleshooting, admins want a view of the connections between servers and a particular storage array. What can the admins do?. -Use the HBEE Insights Dashboard to show connections between servers and storage devices. -Use the HBEE Insights Dashboard to show connections between servers and storage devices. -Use a monitoring template in OpsRamp to create a graph showing server connections. -Use the HBEE Wellness Dashboard to display a connections graph for the storage array. What is one capability added by integrating HBEE VM Essentials with Vm -ware vSphere?. -Updating ESXi hosts' firmware from HBEE VM Essentials Manager. -Provisioning VMs on ESXi hosts and VMs on HBEE VM Essentials hosts from the same interface. -Performing live migrations for VMs deployed on HBEE VM Essentials. -Deploying new HBEE VM Essentials clusters from Vm -ware vSphere. An HBEE partner is working with a cuustomer, who says that they lack a large enough IT staff to stay ahead of help desk requests. What should you explain that OpsRamp provides?. -Unified provisioning of server and storage resources in a hybrid environment. -An overview of HBEE solutions, support contracts, and registered support cases. -AI-powered help in reducing alert noise and identifying root causes. -Automated generation of cases in HBEE support. Which is one benefit a cuustomer receives with HBEE Tech Care?. -Subscription to OpsRamp for continuous monitoring of their environment. -Comprehensive support services for multivendor environments. -Access to the Software Dashboard, which shows the latest software versions for all the covered products. -A dedicated team of experts who provide personalized support services based on the cuustomer's environment. the company has onboarded several HBEE Syn ergy appliances in HBEE Compute Ops Management. What is one action that admins can perform from that cloud solution?. -Defining new logical interconnect group that are pushed down to multiple appliances. -Selecting which external storage volumes are attached to HBEE Syn ergy compute modules. -Configuring the BIOS settings for compute modules in the HBEE Syn ergy appliances. -Applying server profile templates copied from one appliance to other appliances. What is one component in an HBEE Private Cloud AI solution that an admin needs to update separately from the HBEE Private Cloud AI software catalog?. -The control plane nodes' SPP. -The AI Essentials software. -The Red Hat Enterprise Linux OS running on the workers. -The HBEE GreenLake for File Storage software. An HBEE partner is helping a cuustomer onboard HBEE Proo liant servers, which use iLO 6, in HBEE Compute Ops Management. The cuustomer has asked what the minimum software version for iLO 6 is required. What could affect the answer?. -Which iLO license (Advanced or Standard) the servers have. -Which series the HBEE Proo liant servers are (such as 100, 300, or 500). -Whether the cuustomer plans to use the simplified activation key onboarding process. -Whether the cuustomer plans to use HBEE Compute Ops Management only to monitor the servers or also to manage their iLO and BIOS settings. A cuustomer has thirty HBEE Proo liant DL Gen11 servers at a secure site, in which servers cannot connect to the Internet. Which server management option should you recommend?. -HBEE VM Essentials Manager. -HBEE One vieew. -HBEE Compute Ops Management. -HBEE iLO. An admin has found that an update is available for an HBEE Private Cloud AI solution's Private Cloud AI software. Before the admin can install the update, which step is required. -Manually placing the AI optimized workers in maintenance mode. -Updating the HBEE GreenLake for File Storage software to a supported version for the desired software catalog. -Downloading the desired software to each node in the HBEE Private Cloud AI solution. -Running a precheck on the desired new software catalog. Admins want to update the Mellanox kernel drivers running on the AI optimized workers in an HBEE Private Cloud AI solution. What does HBEE recommend?. -Updating the drivers as part of the HBEE Private Cloud AI software catalog update. -Updating the HBEE Aruba Networking CX switches' software first. -Using the OFED drivers downloaded from the HBEE support site. -Running the update from the HBEE AI Essentials UI. An admin is integrating HBEE Compute Ops Management with Data Services Cloud Console to help automate connecting HBEE servers to volumes hosted on HBEE Alletra arrays. The admin is prompted to enter an API client ID and key. Where should the admin obtain these?. -From the API credentials created from an account with Data Services Read Write access. -From the key created when the license for the HBEE Alletra arrays was activated. -From API credentials created in an account with a Data Ops Manager Operator role. -From the key created when activating servers for HBEE Compute Ops Management. What is one way cross-stack analytics in HBEE GreenLake cloud reduces alert fatigue?. -It only escalates alerts related to rare issues and automatically remediates all other alerts. -It automatically suppresses information-only alerts to limit the number of alerts sent to network admins. -It coordinates alert notification with the HBEE support team, reducing the number of alerts the cuustomer has to review. -It uses peer training to analyze typical behavior and determine when an alert is warranted. |




