737 AQP Aircraft General
|
|
Title of test:
![]() 737 AQP Aircraft General Description: General 737 |



| New Comment |
|---|
NO RECORDS |
|
What is the source of power for the JAMCO electric locking system?. 28 Volt DC Bus 1. 28 Volt DC Bus 2. Both 28 Volt DC Bus 1 & 2. During a turn 737-800, what determines the minimum obstruction clearance path. The wingtip radius. The nose wheel radius. The tail radius. If the amber CAB DOOR UNLOCKED light is illuminated on the Jamco Flight Deck Door Control Panel. A fault in the door system or status lights has occurred and security of the door is unknown. A fault in the door system or status lights has occurred and the door always hard locked. It indicates that the door is unlocked. How long will the hard lock push button on the Jamco flight deck door control panel disable the emergency entrance unlock function?. 30 minutes. 5 seconds. 30 seconds. The mechanical lock (pin) located on the Jamco flight deck door_______. relies on electrical power. will not allow the door to be opened by the FLIGHT DECK DOOR EMERGENCY ENTRANCE system. Is used every time the door is closed. With a Jamco flight deck door, if the cabin mounted emergency entrance system is activated, how much time will pass before the door electrically unlocks?. 10 seconds. 30 seconds. It won’t unlock without input from the flight deck. At what cabin altitude will the passenger oxygen system automatically activate?. There is no automatic activation function. 14,000 Feet. 10,000 Feet. How can the pilots manually activate the passenger oxygen system from the flight deck?. The passenger oxygen switch on the aft overhead panel. Pulling the pilot oxygen masks their holder. The passenger oxygen system can’t be manually activated. How can the crew check the oxygen pressure for the Pilot Oxygen System?. The oxygen pressure indicator on the aft overhead panel. The system page on the upper display unit. An oxygen pressure indicator next to the pilots oxygen mask. What does the Normal/100% Switch on the crewmember oxygen mask regulator do if pushed into the 100% position?. Supplies oxygen at positive pressure. Notifies dispatch of an emergency situation. Supplies 100% oxygen on demand. The Bromochlorodifluoromethane, BCF, (Halon 1211) extinguisher is best used for which type of fires. Class B; Flammable liquids. Class C; Live electrical. All of the above. The Type III emergency exits on the B737-800 are located in the passenger cabin over the wings and use a 28 volt DC flight lock system which is designed to ensure that the flight lock will automatically lock during. Takeoff and landing. Inflight. All of the above. Installation of handle covers on the over-wing exits do not need to be verified prior to departure whenever passengers are carried. True. False. What happens to the Jamco flight deck door if the Hard Lock button is pushed after the flight deck door emergency entrance open button is pushed?. The door will automatically HARD LOCK for 30 minutes. dispatch will be sent a discrete message alerting the company of an onboard security incident. “DOOR, DOOR, DOOR” warning message will stop after 30 seconds and the door will electrically unlock for only 5 seconds to allow access. If the FWD and AFT cargo compartments are not locked MASTER CAUTION and_________________ is/are illuminated. The MASTER WARNING light and DOORS ANNUNCIATOR. only the MASTER WARNING light. The DOORS ANNUNICIATOR. How is the potable water system tank pressurized?. The right engine must be started. The APU must be started to pressurize the tank. Engine bleed air or the water system air compressor. Where is the panel that shows the quantity of water in the potable water tank?. The aft overhead panel. Next to the sink in the lavatory. The attendant panel. Where is the hot water heater located?. In the after cargo compartment. Under the lavatory sink. In the EEC compartment. Outboard (retractable) landing lights may be extended at any speed. True. False. When on standby electrical power, which flight deck lights are illuminated?. Only the standby compass light, and selected system information and warning lights. Standby compass light, white dome lights, instrument flood lights, and selected system information and warning lights. All flight deck lights are available. What triggers lights to automatically illuminate when emergency exit switch in the armed position: DC bus No. 1 fails. AC power is turned off. all answers are correct. If the aft flight attendant emergency light switch position is selected on, what happends?. Illuminates all emergency lights and bypasses flight deck control. Illuminates all emergency lights only if the flight deck control switch is in ARMED. Illuminates all emergency lights, landing lights and wing lights. Each Passenger Service Unit (PSU) has ___________ that supply the passenger oxygen system. engine bleed air. individual chemical oxygen generators. individual pressurized oxygen bottles. When the Passenger Oxygen Switch on the aft overhead panel is positioned to ON, the passenger oxygen system is activated automatically by a pressure switch at a cabin altitude of ______ or. 10,000 feet. 14,000 feet. 20,000 feet. What does an illuminated “PASS OXY ON” light on the aft overhead panel indicate: All chemical generators have been activated. The passenger oxygen switch needs maintenance. The passenger oxygen system has been activated. |




