option
Questions
ayuda
daypo
search.php

BIM APPLICATION FUNDAMENTALS

COMMENTS STATISTICS RECORDS
TAKE THE TEST
Title of test:
BIM APPLICATION FUNDAMENTALS

Description:
MCQ Assessment Test

Creation Date: 2016/12/30

Category: Others

Number of questions: 50

Rating:(1)
Share the Test:
Nuevo ComentarioNuevo Comentario
New Comment
NO RECORDS
Content:

Which of the following statements about Visibility/Graphic (VG,VV) is (are) "True"?. Changes made in VG will effect on the all views in project browser. VG is the view specific function. Color filter can be accessed from VG window. Categories on/off can be done in VG window. CAD layers on/off can be done in VG window. Project parameters can be selected from VG window.

FormIt Levels become Revit Levels and support Mass Floors, Floor by Face, and Floor Plan view creation. True. False.

FormIt objects become ___________ which support Wall by Face, Curtain System by Face, and Roof by Face. Revit Mass Families. Revit Families. Generic Models. Topo Surfaces.

______ is one of the Autodesk products and using conceptual BIM with Revit. FormIT. SketchUP. Solidwork. Dynamo.

In Revit structure bracing can be added in plan view or in a __________ view. Framing elevation. Elevation. Ceiling Plan. Default 3D View.

In Revit, structural trusses can be attached to. Roofs. Floor slabs. Roofs or floor slabs.

By default, rebar automatically displays in ______________, not in other views and you need to change its View Visibility States. Section. Structural Plan. Ceiling Plan. Analytical View.

In Revit you can(NOT) sketch a new shape of reinforcement when the standard rebars shape are not exactly same as you want. True. False.

To place structural column in a project, the required structural column families should be loaded into the project and you can place at multiple at Grid intersections. True. False.

You can create a new duct or piping system type by duplicating an existing system type. True. False.

Draw ________ in the early stages of your design to indicate the approximate location of a duct run, or to show a layout that has not been fully sized and it shows as single-line geometry without fittings. placeholder duct. duct. detail line. reference plane.

You can draw flexible ducts using the "Flex Duct" tool or using the "Draw Flex Duct" option on the context menu (right click) on a connector of a mechanical equipment, a duct fitting, or at the end of a duct. The Flex Duct tool is available in _________ . plan view. section view. 3D view. only available in plan and 3D views.

You can convert a section of rigid duct to flexible duct by clicking (Convert to Flex Duct) and then select the air terminal to which the duct that you want to convert is connected. True. False. No need to click on air terminal.

In mechanical setting you can set angle of fittings under Angles and it has followings options. Use any angle only. Use specific angle only. Set an angle increment only. Use any angle, use specific angle and set an angle increment.

Parallel Pipe (1) You can add parallel pipes to an existing piping run that includes pipes and elbows. (2) The "Parallel Pipes" command cannot be used on piping runs that include tees, crosses and valves. 1 is correct. 2 is correct. Both are correct. Both are not correct.

Slope values can be copied to another project using the Transfer Project Standards feature. True. False.

In Revit, the following items can be modeled. flex duct, flex conduit, flex pipe. flex duct round, flex duct rectangular and flex pipe. flex duct round and flex pipe only. flex duct only.

If you want to change the type for a pipe run and use a different routing preference: on the Modify tab, click ____?. Change Type. Reapply Type.

Navisworks has its own native _________ file formats . However Autodesk Navisworks solutions can additionally read a combination of many popular 3D CAD formats. 1. 2. 3. 4.

Which of the following is (are) Navisworks native file format?. .nwa. .nwb. .nwc. .nwd.

Navisworks Simulate can do clash detection and Quantification. True. False.

If you open a dwg file (AutoCAD) with Navisworks manage, it will create a .nwc with same name inside the same folder. True. False.

In the Navisworks TimeLinear window, _________ tab enables you to import tasks from a third-party scheduling software, such as Microsoft Project, Asta, and Primavera. It shows all added data sources, listed in a table format. Tasks. Data Sources. Configure. Simulate.

You can create "Animation" by Using "Saved Viewpoints" in Navisworks. True. False.

In Revit, electrical distribution systems can be created without creating voltage definitions. True. False.

Which of the following statements about sheets is (are) "False"?. A view can be dragged and dropped into a sheet. A sheet can contain both project and sheet information. The same view can be placed into multiple sheets. View cannot be activated and modified in a sheet. A sheet can contain both project parameters and shared parameters.

When linking an architecture Revit model to a MEP Revit projet, the following positioning method is desirable to use. Auto - Origin to Origin. Manual - Origin. Manual - Base Point. Auto - By Shared Coordinates. Auto - Center to Center.

Which is "NOT" used to create a customer title block in Revit?. Lines. Texts. Labels. Viewports.

In a tag family, the label is used to display the information of the element. The label is created by using _______________. Project Parameter. Family Parameter. System Parameter. Shared Parameter.

Which type of parameter is stored in a stand alone notepad. Project Parameter. Family Parameter. Shared Parameter. System Parameter.

In Revit electrical modeling, the cable trays and cable ladders are the loadable family. True. False.

Revit system families can be edited by edit family command. True. False.

Please select all the Revit system families from below. Duct. Cable tray fitting. Lighting Fixture. Wall. Column.

When starting a Revit project, a template is a must to chose and the extension of the template file is ______. .rvt. .rte. .rfa. .rft.

Revit parameters which can be accessed from the properties window is called ______________. Instance parameters. Type parameters.

In a Revit power circuit system, only________ load of the breaker rating can be connected. 80%. 90%. 100%. 120%.

Electrical connecter has a rectangular shape. True. False.

When creating a Revit family, "Metric Generic Model" template is used to create a hosted family. True. False.

Which of the following item is (are) created from "Schedule Properties" window and used in a Revit schedule. Project Parameter. Calculated Value. Shared Parameter. Text.

Please select the "Incorrect" statements from the following. Visual Graphic (VG) is view specific function. New disciplines can be created from properties window. New sub-disciplines can be created from properties window. Project browser shows linked/imported CAD files. Amended families cannot be loaded back in to Revit project with the same name.

Building information modeling (BIM) is the new software for construction industry. True. False.

View range settings are available in elevation views. True. False.

Which of the following is "NOT" a method to create a solid form in the Revit family creation. Extrusion. Revolve. Solid. Sweep. Blend. Swept Blend.

In Revit, a new line styel can be define from Additional Settings under Manage tab and it consists of the following three. Text. Space. Color. Line Weight/Line Projection. Line Pattern. Dot.

In order to connect a power circuit to a DB, the DB must have ________ system which can be select from the option bar. Power. Voltage. Current. Distribution System. Demand Load.

In Revit MEP modeling, Copy/Monitor tool is used to copy the follwing item(s) from a linked Revit architecture model. Floor Plan Views. Elevations. Levels. Grids. Drafting Views.

In Revit, architectural walls are categorized into 3 types and which are: Glass Wall. Basic Wall. Brick Wall. Stacked Wall. Curtain Wall.

In Revit, floor is the system family and can be loaded from Revit Library. True. False.

The display setting of project browser and properties windows can be accessed from _______ tab. Manage. Modify. View. Insert.

Revit default 3D view has __________ visual style. Perspective. Isometric.

Report abuse