FCOM 8
![]() |
![]() |
![]() |
Title of test:![]() FCOM 8 Description: B767 Fire Protection |




New Comment |
---|
NO RECORDS |
Pulling the Engine Fire switch turn off. Fuel. Air. Gen. Hyd. Arms the fire bottles. BDSF: Pushing FWD ARMED. Arms all bottles, turns off both ricirc fans, shuts down the NGS. Arms all bottles, turns off both ricirc fans, shuts down the NGS, Inhibits high flow of both packs. Arms all bottles, turns off both ricirc fans, Inhibits high flow of both packs. Arms all bottles, shuts down the NGS, Inhibits high flow of both packs. BDSF: Pushing AFT ARMED. Arms all bottles, turns off both ricirc fans, shuts down the NGS. Arms all bottles, turns off both ricirc fans, shuts down the NGS, Inhibits high flow of both packs. Arms all bottles, turns off both ricirc fans, Inhibits high flow of both packs. Arms all bottles, shuts down the NGS, Inhibits high flow of both packs. Pulling the APU fire switch. Silences the warning bell. Gen off. Air. Shuts down. Arms the fire bottle. Cargo fire switch to DEPR. Silences warning bell. Illuminates lavatory. Shuts down right pack, remaining pack to low flow. Closes valve - air to cargo areas. Closes main deck trim air valves. Cargo fire switch to DEPR (5 things). Cargo fire switch to DEPR causes. Right pack off, remaining pack to low flow. Right pack off, remaining pack to high flow. Left pack off, remaining pack to low flow. Left pack off, remaining pack to high flow. Main deck smoke detector LEDs on BDSF. Green smoke, amber failed. Amber smoke, Green failed. Green working, red smoke. Red smoke, green working. Wheel well fire protection. There is main gear wheel well fire detection. There is no main gear wheel well fire detection. There is nose gear wheel well fire detection. There is no nose gear wheel well fire detection. The _____ wheel well fire detection system consists of a _____ loop. Main, single. Main, double. Nose, single. Nose, double. Cargo compartment fire protection. BCF has fire supression. BDSF has fire supression. BCF has fire extinguishing. BDSF has fire extinguishing. BCF smoke detectors are fitted to. FWD. AFT. MAIN. BULK. BDSF smoke detectors are fitted to. FWD. AFT. MAIN. BULK. On the BCF. Main cargo compartment fire can be suppressed by depressurising. Main cargo compartment fire can be extinguished. FWD and AFT cargo compartment fire can be suppressed by depressurising. FWD and AFT cargo compartment fire can be extinguished. On the BDSF. Main cargo compartment fire can be suppressed by depressurising. Main cargo compartment fire can be extinguished. FWD and AFT cargo compartment fire can be suppressed by depressurising. FWD and AFT cargo compartment fire can be extinguished. BCF has ____ Cargo fire checklist(s), BDSF has ____ Cargo fire checklist(s). 1,2. 1,1. 2,2. 2,1. BDSF has ____ Cargo fire checklist(s), BCF has ____ Cargo fire checklist(s). 1,2. 1,1. 2,2. 2,1. BCF deals with FWD/AFT cargo fire by _____, BDSF deals with FWD/AFT cargo fire by _____. Suppressing, Extinguishing. Suppressing, Suppressing. Extinguishing, Suppressing. Extinguishing, Extinguishing. Lavatory smoke detection consists of. A single smoke detector with aural alarm and no cockpit annunciation. A single smoke detector, aural alarm and EICAS message. A single smoke detector, aural alarm and cockpit annunciation. |