option
Questions
ayuda
daypo
search.php

ERASED TEST, YOU MAY BE INTERESTED ON REVIT MEP QUIZ LEVEL- 2

COMMENTS STATISTICS RECORDS
TAKE THE TEST
Title of test:
REVIT MEP QUIZ LEVEL- 2

Description:
REVIT MEP QUIZ LEVEL- 2

Author:
MOHAMMAD RUKHSAR
Other tests from this author

Creation Date: 04/08/2014

Category: Others

Number of questions: 50
Share the Test:
New CommentNuevo Comentario
No comments about this test.
Content:
When you first start Revit MEP, the program opens to: A new project. The configuration dialog. The last project you worked on. The Recent Files window.
When no element is selected, the Properties palette: Is dimmed, therefore is NOT selectable. Shows the properties of the last element selected. Shows the properties of the current view. Is NOT visible.
Which of the following element types can a Coordination review with the host project be performed? CAD Import Revit Link CAD Link Revit Import.
Which Types of views can be saved and re-used in other Revit projects? Drafting Views, Schedules, and Sheets Elevations Legends Floor Plans and Ceiling Plans.
Before running the energy analysis, all areas in the project need to be set up with… Light Fixtures Heating Equipment Sun Shade Devices Spaces.
How can view-specific display properties (Scale, Detail Level, View Range, etc.) be applied to existing views? Apply a View Template. Copy and Paste Add a reference callout Set a default View Template in Options.
Which editing command do you use if you want two ducts to come together at a corner? Trim/Extend to corner Edit joins Join Geometry Edit Profile.
Which part(s) of the interface change according to the command you are using? Options Bar Ribbon View Control Toolbar Properties Palette.
How do you change a duct or pipe elbow fitting to a tee fitting? Select the elbow and click + (Plus) Select the elbow and click Convert to Tee button in the ribbon. Select the elbow and use the Type Selector to select a tee fitting. Delete the elbow and replace it with a tee.
Which of the following elements can be copied and monitored? (Select all that apply.) Doors Electrical Devices Levels Ducts.
Which editing command would you use to breal a part of a duct so that you can change the duct type? Align Trim Split Offset.
In work sharing projects, reloading of new architectural Revit links to MEP models can only be done at the central file and not at the local file. True False.
To copy levels from the architectural model by using Copy/Monitor, floor plan views are used. False True.
Which of the following statements about sheets is (are) FALSE? You can insert a view into a sheet by drag and drop method A sheet can contain both shared and project parameters Views cannot be activated and modified in sheets You can place the same view into multiple sheets A sheet can contain both project and sheet information.
New projects inherit which two conditions from the project template? Architectural Revit Link Work Flow Work Sets Families Project Browser.
In work sharing method, MEP sub disciplines are live models and architectural and C&S models are inserted as Revit Links. True False.
Filter settings from a view can be saved as a View Template and can be used in other views. True False.
Which of the following parameter can’t be presented or shown in schedules? Family Parameter Project Parameter Calculated Value Shared Parameter.
When creating sheets, we can use shared parameters. False True.
Visibility/Graphics (VG) Overrides Filter function is a view specific function True False.
In order to create a new MEP hosted family, Metric Generic Model.rft should be used as a template file. True False.
When setting up a Revit MEP project, the following item or (items) are required to be copied from the architectural model by using Copy/Monitor method. Levels Columns Plumbing Fixtures Floor Plans Grids.
For collaborating and co-ordinating among disciplines, work sharing method is preferred over link method because of its real time synchronization feature. False True.
When creating a family by using Metric Generic Model.rft, the two elements will appear in the Ref. Level Floor Plan by default. They are Reference Planes Dash Lines Hidden Lines Center Lines Reference Lines.
A Check Box in properties can be created by using _________ Type of Parameter. Yes/No Check Box Length Tick Text.
When creating Plan Views by using copied levels from architectural linked model, all views will be created under ___________ sub-discipline first. Mech_Gas Mech_Sanitary Mech_Plumbing HVAC Elect.
Families are considered ___________ if they can be changed without having to recreate the elements. Intelligent Parametric Generic Normal Smart.
MEP Revit Template file will be used whenever a new MEP Revit Project is going to be set up and this template file has an extension of .rtf .rvt .rfa .rte .rft.
To link an architectural Revit model, the following positioning method will be used. Manual – Origin Manual – Base Point Auto – By Shared Coordinates Auto – Origin to Origin Auto – Center to Center.
Text leaders must be placed separately. False True.
Ducts, pipes, cable trays and conduits are system families and they can be created as different types. False True.
Which is not used to create a custom title block in Revit? Family Editor Line Text Label Viewport.
Which statement or statements about drafting views is (are) FALSE? Drafting views can show 3D building models You can insert CAD files into drafting views You can adjust view scale and detail level for a drafting view Drafting views can be saved in a separate file and can be inserted into another file We can create section and elevation views from drafting views.
When creating geometry for a Revit family, dimensions can be converted into dimensional parameters for the family. True False.
View Range settings are available in elevation views. False True.
Sectional 3D views are very useful tools for visualization in Revit projects and they can be created by using section views. False True.
Annotation families can be inserted into element families to create nested families. False True.
In order to place spaces, which option must be enabled in a linked architectural model? Place Spaces Allow Zoning Allow Room Zoning Enable Room Bounding.
To divide a space when a space is too large for proper analysis, you can add which element? Zone Separator Space Separator Room Separator Room Spliter.
The available parameters for Building Type and Space Type are based on: ASHRAE standards. ASME standards. AHRI standards. LEED standards.
Duct systems allow you to: Create schedules. Create view filters. Tag ductwork. Coordinate interferences.
Which parameter determines the elevation of the mechanical equipment in the model? Elevation Offset Height Level Offset.
Which tool can you use to place a supply air diffuser? Supply Diffuser Supply Terminal Air Terminal Air System.
You can create a duct system by: Specifying the duct system properties in the Family Editor. Placing components using the Duct Systems tools. Manually adding components to the system. Using the tools in the System Browser.
What are the three system families for ducts? Oval Duct, Rectangular Duct, and Round Duct Low Pressure Duct, Medium Pressure Duct, and High Pressure Duct Supply Duct, Return Duct, and Exhaust Duct Rectangular Sheet Metal Duct, Round Sheet Metal Duct, and Round Stainless Steel Duct.
If you are NOT ready to create ductwork in your model, you can place which elements to claim space for ductwork? Duct Lines Temporary Duct Duct Space holders Duct Placeholders.
Which type parameters mainly define a duct type? System Classification Duct Size Routing Preferences Duct Shape.
What tool can be used to copy the plumbing fixture elements and locations from an architectural model to an MEP model? Copy/Modify Copy/Monitor Copy Plumbing Fixtures Copy Architectural.
In order to create an Underfloor Plumbing Plan, you can modify the: Visibility/Graphic Overrides of a section view. View Range of a section view. Visibility/Graphic Overrides of a floor plan view. View Range of a floor plan view.
You can create piping systems by: Defining the system in the pipe type. Connecting pipe connectors that have been added to a piping system in the Family Editor. Connecting water side components. Using the tools in the System Browser.
Report abuse